LIQUID SERVO SETTINGS DESCRIPTION
• Valve Response 1
Default Value: 100%
Determines the speed of the servo valve when product control error exceeds the Response Threshold
setting.
Decreasing the value will cause the servo valve to run slower.
• Valve Response 2
Default Value: 24%
Determines the speed of the servo valve when product control error is less than the Response Threshold
setting.
Decreasing the value will cause the servo valve to run slower.
• Allowable Error
Default Value: 2%
Determines the percent of error that is allowed prior to the product control system making any flow rate
corrections.
2% - 3% is the normal dead band setting range.
- Too low of a setting value can cause the product control system to continually hunt for the target
application rate.
- Too high of a setting will cause excessive product application error.
• Response Threshold
Default Value: 3
Determines where the control system switches between using Valve Response 1 or Valve Response 2
speed setting.
Leaving all other valve control settings at the default value and making a small adjustment to this setting is
usually all that is required to fine tune system performance.
- Decreasing this value will have the overall effect of speeding up servo valve response.
- Increasing this value will have the overall effect of slowing servo valve response.
LIQUID PWM CONTROL VALVE SETTINGS DESCRIPTION
• PWM Frequency
Default Value: 100
The frequency that the PWM control valve is pulsed at. Typical settings range from 100 - 125. See PWM
valve manufacturer information for recommended settings.
• Gain
Default Value: 800
This setting determines how aggressively the control valve responds when making rate change
adjustments. The higher the value the more aggressive the system response is.
• Zero Offset
Default Value: 30
This setting represents the maximum duty cycle that is sent to the control valve without producing any
hydraulic flow from the PWM valve. Using too high of a Zero Offset value can cause the product control
system to not properly shut off. See PWM valve manufacturer information for recommended settings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ag Leader Integra Display and is the answer not in the manual?

Ag Leader Integra Display Specifications

General IconGeneral
BrandAg Leader
ModelIntegra Display
CategoryMonitor
LanguageEnglish

Related product manuals