252 Firmware Version 6.0
Dickey-john NH3 Heat
Exchanger
In-line Servo 40% 10% 8
Flow Control Valve
or Sprayer Model
(and year if
applicable)
Control System
PWM Frequency
Typical Gain Range
Zero Offset
Allowable Error
Valve Response
1
Valve Response
2
Response Threshold
Apache 510/710/
1010/1210 (2006
and up)
In-line Servo 2% 100% 24%
Use a starting value of 5.
See note below.
All Case IH
sprayers when
using AIM
Command
AIM Command In-
line servo
2% 100% 24% 3
Case IH Surveyor
with A-post
Non-AIM
Command Mode
PWM 
12-volt
122
**700-
900
35 2%
Case IH 3320
Non-AIM
Command Mode
PWM
12-volt
122
**700-
900
35 2%
Case IH 4420 with
A-post
Non-AIM
Command Mode
PWM
12-volt
122
**700-
900
35 2%
Case IH 3200
(KZKCO Valve)
Non-AIM
Command Mode
By-Pass Servo
2% 40% 10% 5
Case IH 4260 with
Raven valve
Non-AIM
Command Mode
By-Pass Servo
2% 100% 24% 3
Flow Control Valve
Control Valve
Configuration
Valve Response
1
Valve Response
2
Response
Threshold

Table of Contents