P12s Near-end background block errors thresh cross 15-min
egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SNBBEgcTHR15
Information The P12s near-end background block errors counter exceeded the provisioned
threshold during a 15-minutes monitoring period (SDH -> PDH).
Alarm category Quality of service (performance monitoring)
ASAP pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Cause Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.