Pluggable Module removed
...................................................................................................................................................................................................................................
Alarm identifier
PMcUNI
Information Although the respective socket has a pluggable module assigned, there is no
pluggable module present.
Alarm category Equipment
ASAP equipment
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications The red fault LED associated to the failed pluggable module is lit.
Cause Pluggable module not present.
Actions Either re-insert or unassign the pluggable module.
Alarm messages
...................................................................................................................................................................................................................................