TU-3 Alarm indication signal received
...................................................................................................................................................................................................................................
Alarm identifier TU3cAIS
Information The VC-3 payload signal is replaced by alarm indication signal. This is
detected by checking the TU-3 pointer bytes for an all 1s pattern.
Alarm category Transmission
ASAP sdhLOPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
Cause In the upstream equipment a defect has been detected, and as a consequent
action, AIS has been inserted in the downstream direction.
Actions Locally no actions need to be taken. Analyze the alarm state of the upstream
equipment and take appropriate measures.
Note(s) In the upstream direction, “VC-3 Remote Defect Indicator” is activated.