EasyManua.ls Logo

Alcatel-Lucent 1643 AMS - STM-1 interface extension board failure

Alcatel-Lucent 1643 AMS
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STM-1 interface extension board failure
...................................................................................................................................................................................................................................
Alarm identifier
STM1XcUPF
Information STM-1 interface extension board failure
Alarm category Equipment
ASAP equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications The red “Fault” LED is lit.
Cause A hardware failure of the STM-1 interface extension is detected.
Actions Remove the STM-1 interface extension board and replace it with another one.
Note(s) As 1643 AM and 1643 AMS systems do not support hardware protection,
STM1XcEQF, and STM1XcUPF are always reported simultaneously as a
reminder that a hardware failure is service affecting.
Alarm messages
...................................................................................................................................................................................................................................
1-166
Alcatel-Lucent - Proprietary
See notice on first page
365-312-803R7.2
Issue 4, May 2007