STM-4 MS Near-end severely ES threshold crossing 15-min
...................................................................................................................................................................................................................................
Alarm identifier MS4NSEScTHR15
Information The STM-4 Multiplex Section near-end severely errored seconds counter
exceeded the provisioned threshold during a 15-minute monitoring period.
Alarm category Quality of service (performance monitoring)
ASAP sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Reported
Local indications –
Cause Possible causes are:
• Dirty optical connector(s).
• Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.