VC-3 Unequipped
...................................................................................................................................................................................................................................
Alarm identifier VC3cUNEQ
Information VC-3 in STM-1 signal not in use.
Alarm category Transmission
ASAP sdhLOPath
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications The red fault LED is lit.
Cause Cross-connection not consistently defined at both sides (for example, at local
and remote station) of a line section.
Actions Define or change the cross-connection at the other side consistently with the
local side.
Note(s) When defining or changing a cross-connection this alarm will almost inevitably
come up as it is practically impossible to issue the changes at both sides at the
same moment.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
1-269