P12s Near-end severely ES threshold crossing 15-min egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SNSESgcTHR15
Information The P12s near-end severely errored seconds counter exceeded the provisioned
threshold during a 15-minutes monitoring period (SDH ->PDH).
Alarm category Quality of service (performance monitoring)
ASAP pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Cause Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.