P12s Near-end background block errors thresh cross 24-hrs
egress
...................................................................................................................................................................................................................................
Alarm identifier
P12SNBBEgcTHR24
Information The P12s near-end background block errors counter exceeded the provisioned
threshold during a 24-hours monitoring period (SDH -> PDH).
Alarm category Quality of service (performance monitoring)
ASAP pdhPath
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Cause Equipment fault(s) in the upstream station.
Actions Check upstream external cabling or equipment.
Alarm messages
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page