SHDSL Regenerator Unit new device detected
...................................................................................................................................................................................................................................
Alarm identifier
SRUcNDD
Information A new SRU has been connected.
Alarm category Equipment
ASAP sdsl
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications –
Cause The respective SRU has been replaced by a new SHDSL device of the same
type.
Actions Perform a configuration download to the new SRU in order to download the
existing configuration data, stored in the management information base (MIB)
of the 1643 AM/ 1643 AMS network element (LTU), to the new SRU.