STM-1 interface extension board removed
...................................................................................................................................................................................................................................
Alarm identifier
STM1XcUNI
Information STM-1 interface extension board is missing
Alarm category Equipment
ASAP equipment
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications The red “Fault” LED is lit.
Cause Although the 1643 AM/ 1643 AMS is provisioned to be equipped with an
STM-1 interface extension board, no STM-1 interface extension board is
present.
Actions Install an STM-1 interface extension board, or change the provisioning.