SDSL Loss of frame alignment
...................................................................................................................................................................................................................................
Alarm identifier
SDSLcLOF
Information Alignment to the frame structure of the SHDSL signal, received at a
customer-side SHDSL port of the LTU, is not possible.
Alarm category Transmission
ASAP sdsl
Alarm severity
(default setting)
Prompt
Reporting state
(default setting)
Reported
Local indications
Cause
The “Loss of sync word” (LOSW) condition has been detected at the respective
customer-side SHDSL port of the LTU. This means that the SHDSL segment
between the respective customer-side SHDSL port of the LTU and the next
attached SHDSL device has failed.
Actions For the failed SHDSL segment:
Verify the correct routing of interconnecting cables.
Verify that the connectors are properly connected at the local and remote
end of the SHDSL segment.
Verify that the receiver at the local end of the SHDSL segment (i.e. at the
LTU where the LOSW condition has been detected) functions properly.
Verify that the transmitter at the remote end of the SHDSL segment (i.e. at
the next attached SHDSL device) functions properly.