Loading...
SHDSL Near-end errored seconds threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
SDSLNEScTHR24
Information The SHDSL near-end errored seconds counter exceeded the provisioned
threshold during a 24-hour monitoring period.
Alarm category Transmission
ASAP sdsl
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
Cause Degraded connection - More ES than the allowed threshold (350) have been
detected in the current 24-hour bin.
Actions Check SHDSL connection on attenuation and crosstalk.
Note(s) The default values of the raise and clear thresholds are fix preset. They cannot
be changed by user provisioning.