User's Manual 1014 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
Parameter Description
SNMP Trusted Managers Table
SNMP Trusted Managers
configure system > snmp settings >
trusted-managers
[SNMPTrustedMgr_x]
The table defines up to five IP addresses of remote trusted
SNMP managers from which the SNMP agent accepts and
processes SNMP Get and Set requests.
For more information, see ''Configuring SNMP Trusted
Managers'' on page 100.
SNMP V3 Users Table
SNMP V3 Users
configure system > snmp v3-users
[SNMPUsers]
The table defines SNMP v3 users.
The format of the ini file table parameter is:
[SNMPUsers]
FORMAT SNMPUsers_Index = SNMPUsers_Username,
SNMPUsers_AuthProtocol, SNMPUsers_PrivProtocol,
SNMPUsers_AuthKey, SNMPUsers_PrivKey,
SNMPUsers_Group;
[\SNMPUsers]
For example:
SNMPUsers 1 = v3admin1, 1, 0, myauthkey, -, 1;
The example above configures user 'v3admin1' with security
level authNoPriv(2), authentication protocol MD5,
authentication text password 'myauthkey', and
ReadWriteGroup2.
For more information, see ''Configuring SNMP V3 Users'' on
page 101.
69.1.6 Serial Parameters
The serial interface parameters are described in the table below.
Table 69-6: Serial Parameters
Parameter Description
[DisableRS232]
Enables the device's RS-232 (serial) port.
[0] = Enabled
[1] = (Default) Disabled
The RS-232 serial port can be used to change the networking
parameters and view error/notification messages. To establish serial
communication with the device, see ''Establishing a CLI Session'' on
page 93.
Note: For the parameter to take effect, a device reset is required.
[SerialBaudRate]
Defines the serial communication baud rate.
The valid values include the following: 1200, 2400, 9600, 14400, 19200,
38400, 57600, or 115200 (default).
Note: For the parameter to take effect, a device reset is required.
[SerialData]
Defines the serial communication data bit.
[7] = 7-bit
[8] = (Default) 8-bit
Note: For the parameter to take effect, a device reset is required.