Version 7.2 1015 Mediant 500L Gateway & E-SBC
User's Manual 69. Configuration Parameters Reference
Parameter Description
[SerialParity]
Defines the serial communication polarity.
[0] = (Default) None
[1] = Odd
[2] = Even
Note: For the parameter to take effect, a device reset is required.
[SerialStop]
Defines the serial communication stop bit.
[1] = (Default) 1-bit (default)
[2] = 2-bit
Note: For the parameter to take effect, a device reset is required.
[SerialFlowControl]
Defines the serial communication flow control.
[0] = (Default) None
[1] = Hardware
Note: For the parameter to take effect, a device reset is required.
69.1.7 Auxiliary and Configuration File Name Parameters
The table below lists the ini file parameters associated with the Auxiliary files. For more
information on Auxiliary files, see ''Loading Auxiliary Files'' on page 791.
Table 69-7: Auxiliary and Configuration File Parameters
Parameter Description
General Parameters
[SetDefaultOnIniFileProcess] Determines if all the device's parameters are set to their defaults
before processing the updated ini file.
[0] = Disable - parameters not included in the downloaded ini file
are not returned to default settings (i.e., retain their current
settings).
[1] = Enable (default).
Note: The parameter is applicable only for automatic HTTP update or
Web ini file upload (not applicable if the ini file is loaded using BootP).
[SaveConfiguration] Determines if the device's configuration (parameters and files) is
saved to flash (non-volatile memory).
[0] = Configuration isn't saved to flash memory.
[1] = (Default) Configuration is saved to flash memory.
Auxiliary and Configuration File Name Parameters
Call Progress Tones File
[CallProgressTonesFilename]
Defines the name of the file containing the Call Progress Tones
definitions.
For the ini file, the name must be enclosed by single apostrophes, for
example, 'cpt_us.dat'.
For more information on how to create and load this file, refer to
DConvert Utility User's Guide.
Note: For the parameter to take effect, a device reset is required.
Prerecorded Tones File Defines the name of the file containing the Prerecorded Tones.