User's Manual 838 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
File Type
Keywords for
Template File
Value Replacing
<FILE> Placeholder
Answering Machine Detection (AMD)
file
amd amd.dat
SSL/TLS Private Key file sslp pkey.pem
pkey<ID>.pem (for multi-certificate
system)
SSL/TLS Root Certificate file sslr root.pem
root<ID>.pem (for multi-certificate
system)
SSL/TLS Certificate file sslc cert.pem
cert<ID>.pem (for multi-certificate
system)
48.2.5 Triggers for Automatic Update
The Automatic Update feature can be triggered by the following:
Upon device startup (reset or power up). To disable this trigger, run the following CLI
command:
(config-system)# automatic-update
(automatic-update)# run-on-reboot off
Periodically:
Specified time of day (e.g., 18:00), configured by the ini file parameter
AutoUpdatePredefinedTime or CLI command configure system > automatic-
update > predefined-time.
Interval between Automatic Updates (e.g., every 60 minutes), configured by the
ini file parameter AutoUpdateFrequency or CLI command configure system >
automatic-update > update-frequency.
Centralized provisioning server request:
Upon receipt of an SNMP request from the provisioning server.
Upon receipt of a special SIP NOTIFY message from the provisioning server. The
NOTIFY message includes an Event header with the AudioCodes proprietary
value, "check-sync;reboot=false", as shown in the example below:
NOTIFY sip:<user>@<dsthost> SIP/2.0
To: sip:<user>@<dsthost>
From: sip:sipsak@<srchost>
CSeq: 10 NOTIFY
Call-ID: 1234@<srchost>
Event: check-sync;reboot=false
To enable the feature:
a. Open the Gateway Advanced Settings page (Setup menu > Signaling &
Media tab > Gateway folder > Gateway Advanced Settings).
b. From the 'Remote Management by Notify' (EnableSIPRemoteReset) drop-
down list, select Enable:
Figure 48-2: Resetting Device by SIP NOTIFY
c. Click Apply.

Table of Contents