45.1.1 Loading Auxiliary Files through Web Interface
The following procedure describes how to load Auxiliary files through the Web interface.
Note:
When loading an ini file through the Auxiliary Files page (as described in this
section), only parameter settings specified in the ini file are applied to the device;
all other parameters remain at their current settings.
If you load an ini file containing Auxiliary file(s), the Auxiliary files specified in the
file overwrite the Auxiliary files currently installed on the device.
To load Auxiliary files through Web interface:
1. Open the Auxiliary Files page:
Toolbar: From the Actions drop-down menu, choose Auxiliary Files.
Navigation tree: Setup menu > Administration tab > Maintenance folder >
Auxiliary Files.
2. Click the Browse button corresponding to the Auxiliary file type that you want to load,
navigate to the folder in which the file is located, and then click Open; the name of the
file appears next to the Browse button.
3. Click the corresponding Load File button.
4. Repeat steps 2 through 3 for each file you want to load.
5. Reset the device with a save-to-flash for your settings to take effect (if you have
loaded a Call Progress Tones file).