Version 7.2 293 Mediant 500L Gateway & E-SBC
User's Manual 15. Services
b. In the 'Quality Status Rate' field (RoutingServerQualityStatusRate), enter the rate
(in sec) at which the device sends QoS reports.
Figure 15-50: Enabling QoS-Based Routing via Routing Server
c. Click Apply.
2. Open the Remote Web Services table (see Configuring Remote Web Services on
page 292 ), and then for the Remote Web Service entry that you configured for the
routing server, do the following:
a. From the 'Type' drop-down list (HTTPRemoteServices_HTTPType), select QoS.
b. Click Apply.
3. Enable voice quality monitoring and RTCP XR, using the 'Enable RTCP XR'
(VQMonEnable) parameter (see Configuring RTCP XR on page 909).
Note: For media metrics calculations, the device's License Key must include voice
quality monitoring and RTCP XR.
15.7 HTTP-based Proxy Services
The device supports the following HTTP-based proxy services:
HTTP Reverse Proxy for Managing Equipment behind NAT:
You can configure the device to function as a reverse HTTP proxy server. This
functionality is required to enable administrators to manage communication equipment
(such as IP Phones) over HTTP when the equipment is located behind NAT (e.g., in
the LAN) and the administrator is located in a public domain (e.g., in the WAN). Thus,
this functionality resolves NAT issues, enabling the administrator to access the IP
Phone's management interface (e.g., embedded Web server).
To support the functionality, the following configuration is required:
1. Enable the HTTP Proxy application (see ''Enabling the HTTP Proxy Application''
on page 294).
2. Define a local, listening HTTP interface for the leg interfacing with the
administrator (see ''Configuring HTTP Interfaces'' on page 295).
Note: It is recommended not to use port 80 as this is the default port used by IP
Phones for their Web-based management interface.
3. Define each HTTP-based managed equipment:
a. Define the URL prefix for accessing the equipment's management interface
(see ''Configuring HTTP Proxy Services'' on page 297). To access the
equipment's management interface, the administrator needs to enter the
following URL in a Web browser: