User's Manual 1158 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
Parameter Description
[TrunkAdministrativeState_x] Defines the administrative state per trunk, where x denotes the
trunk number.
[0] = Lock the trunk; stops trunk traffic to configure the trunk
protocol type.
[1] = shutting down (read only).
[2] = (Default) Unlock the trunk; enables trunk traffic.
iso8859-charset
[ISO8859CharacterSet]
Defines the ISO 8859 character set type (languages) for
representing the alphanumeric string of the calling name (caller ID)
in the forwarded message, for IP-to-Tel and Tel-to-IP calls.
[0] No Accented = Proprietary method where incoming INVITE
messages with any accented characters (e.g., ף ,ם ,י ,ב
, and ),
which are represented in a 2-byte unicode character, are
translated to Latin-only, which are normal one-byte ASCII
characters (a, e, i, o, and u, respectively).
[1] Western European (Default)
[2] Central European
[3] South European
[4] North European
[5] Cyrillic
[6] Arabic
[7] Hebrew
[8] Turkish
69.10.6.2 TDM Bus and Clock Timing Parameters
The TDM Bus parameters are described in the table below.
Table 69-57: TDM Bus and Clock Timing Parameters
Parameter Description
TDM Bus Parameters
PCM Law Select
configure voip > media tdm > pcm-law-
select
[PCMLawSelect]
Determines the type of pulse-code modulation (PCM)
companding algorithm law in input and output TDM bus.
[1] Alaw
[3] MuLaw
The default value is automatically selected according to
the Protocol Type of the selected trunk. If the Protocol
Type is set to NONE, the default is MuLaw.
Note:
For the parameter to take effect, a device reset is
required.
Typically, A-Law is used for most BRI variants.
Idle PCM Pattern
configure voip > media tdm > idle-pcm-
pattern
[IdlePCMPattern]
Defines the PCM Pattern that is applied to the PSTN
timeslot (B-channel) when the channel is idle.
The range is 0 to 255. The default is set internally
according to the Law select 1 (0xFF for Mu-Law; 0x55
for A-law).
Note: For the parameter to take effect, a device reset is
required.