Version 7.2 1157 Mediant 500L Gateway & E-SBC
User's Manual 69. Configuration Parameters Reference
Parameter Description
started when a Q.931 Alert message is received. The timer is
stopped when a Q.931 Connect/Disconnect message is received
from the other side. If no Connect or Disconnect message is
received within the duration of T301, the call is cleared.
The valid range is 0 to 2400. The default is 0 (i.e., the default T301
timer value - 180 seconds - is used). If set to any value other than
0, it overrides the timer with this value.
Note:
For the parameter to take effect, a device reset is required.
The parameter is applicable only to the QSIG variant.
Trace Level
configure voip > interface e1-
t1|bri > trace-level
[TraceLevel]
Defines the trace level:
[0] No Trace (default)
[1] Full ISDN Trace
[2] Layer 3 ISDN Trace
[3] Only ISDN Q.931 Messages Trace
[4] Layer 3 ISDN No Duplication Trace
[TrunkLifeLineType] Defines the scenarios upon which the device activates PSTN
Fallback for digital interfaces (BRI). PSTN Fallback automatically
re-routes Tel calls initially destined to the IP network to the PSTN
instead, upon power outage, a LAN disconnection, or loss of IP
connectivity (i.e., no ping), thereby guaranteeing call continuity.
PSTN Fallback is provided by two ports, where in the event of a
PSTN Fallback, the device automatically connects the two ports
using a metallic relay switch. For example, if one port is connected
to a PBX and the other port to the PSTN, upon a power outage,
calls originating from the PBX are routed directly to the PSTN
(instead of to the IP network).
[0] = (Default) PSTN Fallback is activated only upon power
outage.
[2] = PSTN Fallback is activated upon one of the following:
Power outage
Loss of IP network connectivity (i.e., no ping)
Note:
For the parameter to take effect, a device reset is required.
PSTN Fallback is supported only on specific hardware
configurations and where dual digital ports are provided.
For more information on cabling the device for PSTN Fallback,
refer to the Hardware Installation Manual.
[AdminState] Defines the administrative state for all trunks.
[0] = Lock the trunk; stops trunk traffic to configure the trunk
protocol type.
[1] = Shutting down (read only).
[2] = (Default) Unlock the trunk; enables trunk traffic.
Note:
For the parameter to take effect, a device reset is required.
When the device is locked from the Web interface, the
parameter changes to 0.
To define the administrative state per trunk, use the
TrunkAdministrativeState parameter.