User's Manual 69. Configuration Parameters Reference
Parameter Description
User Side:
0-63: Static TEI is used.
127: Dynamic TEI allocation is supported (TEI request
procedure initiated).
configure voip > interface bri > tei-
assign-trigger
[BriTEIAssignTrigger_x]
Defines when to start the TEI assignment procedure.
The valid values are (bit-field parameter):
Bit #0: LAYER1_ACTIVATION
Bit #1: BRI_PORT_CONFIG
Bit #2: CALL_ESTABLISH
The default is 0x04 (Bit #2).
Note: The parameter is applicable only to the User side (for
Dynamic TEI).
configure voip > interface bri > tei-
remove-trigger
[BriTEIRemoveTrigger_x]
Defines the following:
Network Side: When to "forget"
all existing TEIs and wait for
the User side to start a new TEI assignment procedure.
This is also applicable to static TEI.
User Side: When to start a new TEI assignment verification
procedure.
The valid values are (bit-field parameter):
Bit #0: LAYER1_DEACTIVATION
Bit #1: BRI_DL_RELEASED
Bit #2: TEI_0_P2MP_NET_SIDE (Note: this value is used
to skip TEI=0 SABMEs when the port is defined as P2MP
NET side.)
The default is 0x00.
69.10.7 ISDN and CAS Interworking Parameters
The ISDN and CAS interworking parameters are described in the table below.
Table 69-59: ISDN and CAS Interworking Parameters
Parameter Description
ISDN Parameters
Send Local Time To ISDN
Connect
[SendLocalTimeToISDNCon
nect]
Determines the device's
handling of the date and time sent in the ISDN
Connect message (Date / Time IE) upon receipt of SIP 200 OK
messages.
[0] Disable = (Default) If the SIP 200 OK includes the Date header,
the device sends its value in the ISDN Connect Date / Time IE. If
the 200 OK does not include this header, it does not add the Date /
Time IE to the sent ISDN Connect message.
[1] Enable = If the SIP 200 OK includes the Date header, the
device sends its value (i.e. date and time) in the ISDN Connect
Date / Time IE. If the 200 OK does not include this header, the
device uses its internal, local date and time for the Date / Time IE,
which it adds to the sent ISDN Connect message.
[2] Always Send Local Date and Time = The device always sends
its local date and time (obtained from its internal clock) to PBXs in