User's Manual 236 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
15.2.2 Configuring SIP Recording Rules
The SIP Recording Rules table lets you configure up to 30 SIP-based media recording
rules. A SIP Recording rule defines call routes that you want to record. For an overview of
the feature, see ''SIP-based Media Recording'' on page 229.
Note:
• To configure the device's timestamp format (local or UTC) in SIP messages sent
to the SRS, see the SIPRecTimeStamp parameter.
• To view the total number of currently active SIPRec signaling sessions, use the
CLI command show voip calls statistics siprec. For more information, refer to
the CLI Reference Guide.
The following procedure describes how to configure SIP Recording rules through the Web
interface. You can also configure it through ini file (SIPRecRouting) or CLI (configure voip >
sip-definition sip-recording sip-rec-routing).
To configure a SIP Recording Routing rule:
1. Open the SIP Recording Rules table (Setup menu > Signaling & Media tab > SIP
Recording folder > SIP Recording Rules).
2. Click New; the following dialog box appears:
The figure above shows a configuration example where the device records calls made
by IP Group "ITSP" to IP Group "IP-PBX" that have the destination number prefix
"1800". The device records the calls from the leg interfacing with IP Group "IP PBX"
(peer) and sends the recorded media to IP Group "SRS-1". SRS redundancy has also
been configured, where IP Group "SRS-1" is the active SRS and IP Group "SRS-2"
the standby SRS.
3. Configure a SIP recording rule according to the parameters described in the table
below.