Version 7.2 1095 Mediant 500L Gateway & E-SBC
User's Manual 69. Configuration Parameters Reference
Parameter Description
incoming calls and only when all channels are idle (when
graceful period ends or when all channels become idle before
graceful period ends, whichever occurs first), does the device
send an alarm on the trunk.
When connectivity is restored for the Busy Out feature or the Trunk
Group is unlocked, the device clears the alarm.
Note: For partially configured trunks (only some channels
configured), this option only rejects new calls for the trunk; no alarm
is sent.
Note:
The parameter is applicable only to digital interfaces.
When configuring out-of-service behavior per trunk
(DigitalOOSBehaviorForTrunk_x), you must stop the trunk (Stop
Trunk button in the Trunk Settings page), configure the parameter,
and then restart the trunk (Apply Trunk Settings button in the Trunk
Settings page) for the settings to take effect.
To define out-of-service behavior for all trunks (globally), see the
DigitalOOSBehavior parameter.
For locking/unlocking Trunk Groups in the Trunk Group Settings
table, see Configuring Trunk Group Settings on page 503.
For a description of the Busy Out feature and for enabling the
feature, see the EnableBusyOut parameter.
To configure the graceful out-of-service period, see the
GracefulBusyOutTimeout parameter.
If the ISDN variant does not support the configured out-of-service
option of the parameter, the device sets the parameter to Default
[0].
The x in the ini file parameter name denotes the trunk number,
where 0 is Trunk 1.
Digital Out-Of-Service
Behavior
dig-oos-behavior
[DigitalOOSBehavior]
Defines the method for setting all digital trunks to out-of-service state.
To configure the out-of-service method per trunk, see the
DigitalOOSBehaviorForTrunk_x parameter.
[0] Default = (Default) For a detailed description, see option [0] of
the DigitalOOSBehaviorForTrunk_x parameter (per trunk setting).
[1] Service = Sends an ISDN Service message indicating out-of-
service state (or in-service). For a detailed description, see option
[1] of the DigitalOOSBehaviorForTrunk_x parameter (per trunk
setting).
[2] D-Channel = Takes the D-Channel down or brings it up. For a
detailed description, see option [2] of the
DigitalOOSBehaviorForTrunk_x parameter (per trunk setting).
[3] Alarm = Sends or clears a PSTN Alarm Indication Signal (AIS)
alarm. For a detailed description, see option [3] of the
DigitalOOSBehaviorForTrunk_x parameter (per trunk setting).
Note:
The parameter is applicable only to digital interfaces.
When using the parameter to configure out-of-service behavior for
all trunks, you must reset the device for the settings to take effect.
If the ISDN variant does not support the configured out-of-service
option of the parameter, the device sets the parameter to Default
[0].