Version 7.2 427 Mediant 500L Gateway & E-SBC
User's Manual 19. SIP Message Manipulation
2. Click New; the following dialog box appears:
Figure 19-8: Pre-Parsing Manipulation Sets Table - Add Dialog Box
3. Configure a Pre-Parsing Manipulation Set name according to the parameters
described in the table below.
4. Click Apply.
Pre-Parsing Manipulation Set Table Parameter Descriptions
Parameter Description
Index
[PreParsingManipulation
Sets_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Name
name
[PreParsingManipulation
Sets_Name]
Defines a descriptive name, which is used when associating the row in
other tables.
The valid value is a string of up to 40 characters.
Note: Each row must be configured with a unique name.
5. In the Pre-Parsing Manipulation Sets table, select the row, and then click the Pre-
Parsing Manipulation Rules link located below the table; the Pre-Parsing
Manipulation Rules table appears.
6. Click New; the following dialog box appears:
Figure 19-9: Pre-Parsing Manipulation Rules Table - Add Dialog Box
7. Configure a rule according to the parameters described in the table below.
8. Click New, and then save your settings to flash memory.