Version 7.2 43 Mediant 500L Gateway & E-SBC
User's Manual 4. Configuring VoIP LAN Interface for OAMP
To configure the OAMP IP address through CLI:
1. Connect the RS-232 port of the device to the serial communication port on your
computer. For more information, refer to the Hardware Installation Manual.
Figure 4-3: Serial Cabling to PC
2. Establish serial communication with the device using a terminal emulator program
such as HyperTerminal, with the following communication port settings:
• Baud Rate: 115,200 bps
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
3. At the CLI prompt, type the username (default is "Admin" - case sensitive):
Username: Admin
4. At the prompt, type the password (default is "Admin" - case sensitive):
Password: Admin
5. At the prompt, type the following:
enable
6. At the prompt, type the password again:
Password: Admin
7. Access the Network configuration mode:
# configure network
8. Access the IP Interfaces table:
(config-network)# interface network-if 0
9. Configure the IP address:
(network-if-0)# ip-address <IP address>
10. Configure the prefix length:
(network-if-0)# prefix-length <prefix length / subnet mask, e.g., 16>