To configure BRI call forwarding:
1. Open the Supplementary Services table (see Configuring Multi-Line Extensions and
Supplementary Services on page 599), and then configure BRI line extensions with
the required call forwarding parameters:
For more information, see Configuring Multi-Line Extensions and Supplementary
Services on page 599.
2. Enable BRI call forwarding, by using the following ini file parameter setting:
BRICallForwardHandling=1
3. Open the Trunk Group table (Configuring Trunk Groups on page 501), and then
configure a Trunk Group (e.g., 1) for the BRI ports.
4. Open the Trunk Group Settings table (see Configuring Trunk Group Settings on page
503), and then for the Trunk Group ID to which the BRI ports belong, set the 'Channel
Select Mode' parameter to Select Trunk by Supp-Serv Table:
5. Open the Trunk Settings page (see Configuring Trunk Settings on page 491), and
then make sure that you configure the BRI ports with the following settings:
• 'Protocol Type': BRI EURO ISDN
• 'ISDN Termination Side': Network Side