User's Manual 606 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
The following procedure describes how to configure Charge Codes through the Web
interface. You can also configure it through ini file (ChargeCode) or CLI (configure voip >
gateway analog charge-code).
To configure a Charge Code:
1. Open the Charge Codes table (Setup menu > Signaling & Media tab > Gateway
folder > Routing > Charge Codes).
2. Click New; the following dialog box appears:
Figure 27-15: Charge Codes Table - Add Dialog Box
3. Configure a Charge Code according to the parameters described in the table below.
4. Click Apply.
Table 27-7: Charge Codes Table Parameter Descriptions
Parameter Description
Index
[ChargeCode_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Name
charge-code-name
[ChargeCode_ChargeCodeName]
Defines a descriptive name, which is used when associating the
row in other tables.
The valid value is a string of up to 40 characters.
Note: Each row must be configured with a unique name.
End Time (1 - 4)
end-time-<1-4>
[ChargeCode_EndTime<1-4>]
Defines the end of the time period in a 24 hour format, hh. For
example, "04" denotes 4 A.M.
Note:
The first time period always starts at midnight (00).
It is mandatory that the last time period of each rule end at

Table of Contents