User's Manual 608 Document #: LTRT-10532
Mediant 500L Gateway & E-SBC
'MWI Off Digit Pattern' (MWIOffCode): Defines the digit code indicating no
messages waiting for a specific extension.
'MWI On Digit Pattern' (MWIOnCode): Defines the digit code indicating messages
waiting for a specific extension.
'MWI Suffix Pattern' (MWISuffixCode): Defines the digit code used as a suffix for
'MWI On Digit Pattern' and 'MWI Off Digit Pattern'.
'MWI Source Number' (MWISourceNumber): Defines the calling party's phone
number in the Q.931 MWI Setup message to PSTN.
4. Under the SMDI group, configure Simplified Message Desk Interface (SMDI):
'Enable SMDI' (SMDI): Enables SMDI interface on the device.
'SMDI Timeout' (SMDITimeOut): Defines the time (in msec) that the device waits
for an SMDI Call Status message before or after a Setup message is received.
5. Under the Digit Patterns group, configure the digit patterns used by the PBX to
indicate various services:
'Forward on Busy Digit Pattern Internal' (DigitPatternForwardOnBusy): Defines
the digit pattern to indicate 'call forward on busy' when the original call is received
from an internal extension.
'Forward on No Answer Digit Pattern Internal' (DigitPatternForwardOnNoAnswer):
Defines the digit pattern to indicate 'call forward on no answer' when the original
call is received from an internal extension.
'Forward on Do Not Disturb Digit Pattern Internal' (DigitPatternForwardOnDND):
Defines the digit pattern to indicate 'call forward on do not disturb' when the
original call is received from an internal extension.
'Forward on No Reason Digit Pattern Internal' (DigitPatternForwardNoReason):
Defines the digit pattern to indicate 'call forward with no reason' when the original
call is received from an internal extension.
'Forward on Busy Digit Pattern External' (DigitPatternForwardOnBusyExt):
Defines the digit pattern to indicate 'call forward on busy' when the original call is
received from an external line.
'Forward on No Answer Digit Pattern External'
(DigitPatternForwardOnNoAnswerExt): Defines the digit pattern to indicate 'call
forward on no answer' when the original call is received from an external line.
'Forward on Do Not Disturb Digit Pattern External'
(DigitPatternForwardOnDNDExt): Defines the digit pattern to indicate 'call forward
on do not disturb' when the original call is received from an external line.
'Forward on No Reason Digit Pattern External'
(DigitPatternForwardNoReasonExt): Defines the digit pattern to indicate 'call
forward with no reason' when the original call is received from an external line.
'Internal Call Digit Pattern' (DigitPatternInternalCall): Defines the digit pattern to
indicate an internal call.
'External Call Digit Pattern' (DigitPatternExternalCall): Defines the digit pattern to
indicate an external call.
'Disconnect Call Digit Pattern' (TelDisconnectCode): Defines a digit pattern that
when received from the Tel side indicates the device to disconnect the call.
'Digit To Ignore Digit Pattern' (DigitPatternDigitToIgnore): Defines a digit pattern
that if received as Src (S) or Redirect (R) numbers is ignored and not added to
that number.