Version 7.2 617 Mediant 500L Gateway & E-SBC
User's Manual 28. Analog Gateway
Note:
• If an FXS port receives 'private' or 'anonymous' strings in the SIP From header,
the calling name or number is not sent to the Caller ID display.
• If the device detects Caller ID on an FXO line (EnableCallerID = 1), it uses this
Caller ID instead of the Caller ID configured in the Caller Display Information table.
The following procedure describes how to configure caller ID through the Web interface.
You can also configure it through ini file (CallerDisplayInfo) or CLI (configure voip >
gateway analog caller-display-info).
To configure caller ID:
1. Open the Caller Display Information table (Setup menu > Signaling & Media tab >
Gateway folder > Analog Gateway > Caller Display Information).
2. Select the row corresponding to the port that you want to configure, and then click
Edit; the following dialog box appears:
3. Configure caller ID per port according to the parameters described in the table below.
4. Click Apply.
Table 28-3: Caller Display Information Table Parameter Descriptions
Parameter Description
General
Index
[CallerDisplayInfo_Index]
(Read-only) Displays the index number of the table row.
Module
[CallerDisplayInfo_Module]
(Read-only) Displays the module number on which the port is
located.
Port
[CallerDisplayInfo_Port]
(Read-only) Displays the port number.
Port Type
[CallerDisplayInfo_PortType]
(Read-only) Displays the port type (FXS or FXO).
Caller Display
Display String
display-string
Defines the Caller ID string.
The valid value is a string of up to 18 characters.