EasyManuals Logo

Cisco 500 Series Administration Guide

Cisco 500 Series
653 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
VLAN Management
Regular VLANs
265 Cisco 500 Series Stackable Managed Switch Administration Guide
14
- Access—The interface is an untagged member of a single VLAN. A port
configured in this mode is known as an access port.
- Trunk—The interface is an untagged member of one VLAN at most, and
is a tagged member of zero or more VLANs. A port configured in this
mode is known as a trunk port.
- Customer—Selecting this option places the interface in QinQ mode. This
enables you to use your own VLAN arrangements (PVID) across the
provider network. The device is in Q-in-Q mode when it has one or more
customer ports. See QinQ.
- Private VLAN - Host—Select to set the interface as either isolated or
community. Then select either an isolated or community VLAN in the
Secondary VLAN - Host field.
- Private VLAN - Promiscuous—Select to set the interface as promiscuous.
• Administrative PVID—Enter the Port VLAN ID (PVID) of the VLAN to which
incoming untagged and priority tagged frames are classified. The possible
values are 1 to 4094.
• Frame Type—Select the type of frame that the interface can receive.
Frames that are not of the configured frame type are discarded at ingress.
These frame types are only available in General mode. Possible values are:
- Admit All—The interface accepts all types of frames: untagged frames,
tagged frames, and priority tagged frames.
- Admit Tagged Only—The interface accepts only tagged frames.
- Admit Untagged Only—The interface accepts only untagged and
priority frames.
• Ingress Filtering—(Available only in General mode) Select to enable ingress
filtering. When an interface is ingress filtering enabled, the interface discards
all incoming frames that are classified as VLANs of which the interface is not
a member. Ingress filtering can be disabled or enabled on general ports. It is
always enabled on access ports and trunk ports.
• Primary VLAN—Select the primary VLAN in the private VLAN. The primary
VLAN is used to allow Layer 2 connectivity from promiscuous ports to
isolated ports and to community ports.
• Secondary VLAN - Host—Select an isolated or community VLAN for those
hosts that only require a single secondary VLAN.

Table of Contents

Other manuals for Cisco 500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 500 Series and is the answer not in the manual?

Cisco 500 Series Specifications

General IconGeneral
ModelCisco 500 Series
CategorySwitch
MountingRack-mountable
ManagementWeb-based, CLI, SNMP
Ports24, 48
Port Speed10/100/1000 Mbps
PoE SupportAvailable on some models
Switching CapacityUp to 176 Gbps
MAC Address Table Size16, 000 entries
SecurityACLs, 802.1X
Quality of Service (QoS)Yes
DimensionsVaries by model
WeightVaries by model
Humidity10% to 90% non-condensing
Power SupplyInternal
Power ConsumptionVaries by model
Jumbo Frame SupportUp to 9216 bytes

Related product manuals