2-529
Catalyst 3750 Switch Command Reference
OL-8552-07
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
show diagnostic
Command History
Usage Guidelines If you do not enter a switch num, information for all switches is displayed.
In the command output, the possible testing results are as follows:
• Passed (.)
• Failed (F)
• Unknown (U)
Examples This example shows how to display the online diagnostics that are configured on a switch:
Switch# show diagnostic content switch 3
Switch 3:
Diagnostics test suite attributes:
B/* - Basic ondemand test / NA
P/V/* - Per port test / Per device test / NA
D/N/* - Disruptive test / Non-disruptive test / NA
S/* - Only applicable to standby unit / NA
X/* - Not a health monitoring test / NA
F/* - Fixed monitoring interval test / NA
E/* - Always enabled monitoring test / NA
A/I - Monitoring is active / Monitoring is inactive
R/* - Switch will reload after test list completion / NA
P/* - will partition stack / NA
Test Interval Thre-
ID Test Name attributes day hh:mm:ss.ms shold
==== ================================== ============ =============== =====
1) TestPortAsicStackPortLoopback B*N****A** 000 00:01:00.00 n/a
2) TestPortAsicLoopback B*D*X**IR* not configured n/a
3) TestPortAsicCam B*D*X**IR* not configured n/a
4) TestPortAsicRingLoopback B*D*X**IR* not configured n/a
5) TestMicRingLoopback B*D*X**IR* not configured n/a
6) TestPortAsicMem B*D*X**IR* not configured n/a
This example shows how to display the online diagnostic results for a switch:
Switch# show diagnostic result switch 1
Switch 1: SerialNo :
Overall diagnostic result: PASS
Test results: (. = Pass, F = Fail, U = Untested)
1) TestPortAsicStackPortLoopback ---> .
2) TestPortAsicLoopback ------------> .
3) TestPortAsicCam -----------------> .
4) TestPortAsicRingLoopback --------> .
5) TestMicRingLoopback -------------> .
6) TestPortAsicMem -----------------> .
Release Modification
12.2(25)SEE This command was introduced.