Select the Input signal spectrum inversion
setting, which allows the operator to track and
select inverted and non-inverted digital
signals. This is normally used to automatically
reject or filter out unwanted signals.
Auto, Normal, or
Opposite.
Auto - The signal is
tracked and inverted for
correct selection, as
required.
Opposite - The signal is
always inverted.
Normal - The signal is not
inverted.
Select the Network ID of the uplink signal the
receiver is to receive. The receiver's Network
ID must match the Network ID associated with
the transmitted signal.
1 to 65535. The default
value is 1.
Set the power output of RF1 to the external
LNB.
Off, 13V, 18V, V-NIT, or
H-NIT.
V-NIT and H-NIT will use
vertical and horizontal
polarity until it is
automatically read from
the NIT.
Note: Power will not be
applied to the LNB when
set to Off.
For dual band applications, select whether to
transmit the 22 kHz tone Local Oscillator
control signal of RF1.
On, Off, or Auto.
Auto uses the crossover
frequency to determine if
the tone is transmitted.
IP Input
Note: This is for D9854-I only.
Select the input to be active.
Note: Setting a new input to be active will
deactivate the currently active input.