307
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
PSB non-
compliant
Clear
PSB compliant
Major
900
Pri Flash Fail
Set
Contact Customer
Service (%s fail at
%d)
Cause: FLASH
driver operation
%s (one of ERASE,
WRITE,
BLANK_CHECK
or READ_WRITE)
failed on Primary
(5514) FLASH
offset %d.
Remedy: Contact
Cisco Services to
replace the unit.
The FLASH
device
hardware
failed.
Major
910
Sec Flash Fail
Set
Contact Customer
Service (%s fail at
%d)
Cause: FLASH
driver operation
%s (one of ERASE,
WRITE,
BLANK_CHECK
or READ_WRITE)
failed on
Secondary (7109)
FLASH offset %d.
Remedy: Contact
Cisco Services to
replace the unit.
The FLASH
device
hardware
failed.
Major
920
Settings Lost
Set
Stored
configuration
incomplete.
Contact Customer
Service
Cause: Corrupted
database record
was found while
populating the
DBR partition.
Remedy: Contact
Cisco Services.
The settings
database
detects
corruption.
Major
950
Signal Status
Set
ASI Signal - No
Content
Cause: Loss of
ASI/RF lock. Loss
of Transport data.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.
ASI Link
Locked, but no
TS content.
Minor
1000

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C

Related product manuals