EasyManuals Logo

Cisco D9854 Installation And Configuration Guide

Cisco D9854
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #378 background imageLoading...
Page #378 background image
Chapter 6 Service and Maintenance
354
Warning
Message
Type
Message
Cause/Remedy
Description
ID
CAT timeout #
Set
CAT timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Conditional Access
Table was never
received.
76000
CAT timeout #
Set
CAT is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Conditional Access
Table.
76000
CAT timeout #
Clear
CAT fault cleared
76000
DRT timeout #
Set
DRT # timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
Disaster Recovery
Table was never
received.
77000
DRT timeout #
Set
DRT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Disaster Recovery
Table.
77000
DRT timeout #
Clear
DRT fault cleared
77000

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK
Symbol Rate1 to 45 Msps
Power Supply100-240 VAC, 50/60 Hz
Power Consumption40W (typical)
Operating Temperature0°C

Related product manuals