2-7
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
alarm-contact
alarm-contact
To configure triggers and severity levels for external alarms, use the alarm-contact command in global
configuration mode. To remove the configuration, use the no form of this command.
alarm-contact {contact-number {description string | severity {critical | major | minor} | trigger
{closed | open}} | all {severity {critical | major | minor} | trigger {closed | open}}
no alarm-contact {contact-number {description | severity | trigger} | all {severity | trigger}
Defaults No alarms are configured.
Command Modes Global configuration
Command History
Usage Guidelines The no alarm-contact contact-number description sets the description to an empty string.
The no alarm-contact {contact-number | all} severity sets the alarm-contact severity to minor.
The no alarm-contact {contact-number | all} trigger sets the external alarm-contact trigger to closed.
You can verify your settings by entering the show env alarm-contact or the show running-config
privileged EXEC command.
contact-number
Configures a specific alarm contact number. The range is 1 to 4.
description
string
Adds a description for the alarm contact number. The description string can be up to
80 alphanumeric characters in length and is included in the system message
generated when the alarm is triggered.
all Configures all alarm contacts.
severity Sets the severity level that is set when the alarm is triggered. The severity is included
in the alarm notification. Entering no alarm-contact severity sets the severity to
minor.
critical Sets severity level as critical.
major Sets severity level as major.
minor Sets severity level as minor.
trigger Sets the state that triggers the alarm, whether the connected circuit is open or closed.
Entering no alarm-contact trigger sets the trigger to closed.
closed Specifies that the alarm is triggered when the contact is closed.
open Specifies that the alarm is triggered when the contact is open.
Release Modification
12.2(52)EY This command was introduced.

Table of Contents

Other manuals for Cisco ME 3600X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ME 3600X and is the answer not in the manual?

Cisco ME 3600X Specifications

General IconGeneral
BrandCisco
ModelME 3600X
CategorySwitch
LanguageEnglish

Related product manuals