EasyManuals Logo

Cisco ME 3600X User Manual

Cisco ME 3600X
628 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #327 background imageLoading...
Page #327 background image
-51
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter
show env
These are examples of output from the show env temperature and show env temperature status
commands:
Switch> show env temperature
SYSTEM TEMPERATURE is GREEN
Switch> show env temperature status
SYSTEM Temperature Value: 35.5 Degree Celsius
SYSTEM Temperature State: GREEN
SYSTEM Low Temperature Alert Threshold: 0.0 Degree Celsius
SYSTEM Low Temperature Shutdown Threshold: -20.0 Degree Celsius
SYSTEM High Temperature Alert Threshold: 58.0 Degree Celsius
SYSTEM High Temperature Shutdown Threshold: 80.0 Degree Celsius
POWER SUPPLY 1 Temperature Value: 32.7500 Degree Celsius
POWER SUPPLY 1 Temperature Alert Threshold: 85.0000 Degree Celsius
POWER SUPPLY 1 Temperature Shutdown Threshold: 110.0000 Degree Celsius
FAN TRAY 2: No Temperature Information Provided
Related Commands Command Description
system env temperature
threshold alert
Configures the system temperature thresholds.
alarm-contact Configures alarm contacts.

Table of Contents

Other manuals for Cisco ME 3600X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ME 3600X and is the answer not in the manual?

Cisco ME 3600X Specifications

General IconGeneral
BrandCisco
ModelME 3600X
CategorySwitch
LanguageEnglish

Related product manuals