EasyManuals Logo

Cisco ME 3600X User Manual

Cisco ME 3600X
628 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #376 background imageLoading...
Page #376 background image
-100
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-28238-01
Chapter
show logging onboard
05/13/2006 07:25:24 36 -- -- -- -- -- -- -- -- -- -- --
05/13/2006 08:25:24 35 -- -- -- -- -- -- -- -- -- -- --
<output truncated>
This is an example of output from the show logging onboard uptime summary command:
Switch# show logging onboard uptime summary
--------------------------------------------------------------------------------
UPTIME SUMMARY INFORMATION
--------------------------------------------------------------------------------
First customer power on : 03/01/1993 00:03:50
Total uptime : 0 years 0 weeks 3 days 21 hours 55 minutes
Total downtime : 0 years 0 weeks 0 days 0 hours 0 minutes
Number of resets : 2
Number of slot changes : 1
Current reset reason : 0x0
Current reset timestamp : 03/01/1993 00:03:28
Current slot : 1
Current uptime : 0 years 0 weeks 0 days 0 hours 55 minutes
--------------------------------------------------------------------------------
Reset | |
Reason | Count |
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
This is an example of output from the show logging onboard voltage summary command:
Switch# show logging onboard voltage summary
--------------------------------------------------------------------------------
VOLTAGE SUMMARY INFORMATION
--------------------------------------------------------------------------------
Number of sensors : 8
Sampling frequency : 60 seconds
Maximum time of storage : 3600 minutes
--------------------------------------------------------------------------------
Sensor | ID | Maximum Voltage
--------------------------------------------------------------------------------
12.00V 0 12.567
5.00V 1 5.198
3.30V 2 3.439
2.50V 3 2.594
1.50V 4 1.556
1.20V 5 1.239
1.00V 6 0.980
0.75V 7 0.768
--------------------------------------------------------------------------------
Nominal Range Sensor ID
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
Related Commands Command Description
clear logging onboard Removes the OBFL data in the flash memory.
hw-module module logging onboard Enables OBFL.

Table of Contents

Other manuals for Cisco ME 3600X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ME 3600X and is the answer not in the manual?

Cisco ME 3600X Specifications

General IconGeneral
BrandCisco
ModelME 3600X
CategorySwitch
LanguageEnglish

Related product manuals