2. Enter the appropriate information in the form as described below:
Select None or a specific custom protocol from the drop-down list. In some cases, a
customer specific protocol may have been created. When selected, a group of options
specific to that protocol are made available.
Select Aux Serial Port, Main Serial Port, or a User Socket from the drop-
down list.
Crisplant
Device
Type/Error
Definition
Select DLA Device/Errors or a ASI-Axiom/Errors from the drop-down list.
This allows selection of different device types, as the error codes required
by Crisplant vary from device to device.
DLA Device/Errors: select when using current Datalogic devices
ASI-Axiom/Errors: Select when using legacy Accu-Sort devices
Crisplant
Manufacturer
ID
This field is determined by the Crisplant Device Type/Error Definition
selected above and cannot be edited.
This defines the "Scanner Identity" byte of the Error and Heartbeat
messages of the Crisplant Protocol.
Select the check box to enable the transmission of the Heartbeat message.
Enter a value in milliseconds to define the amount of time between two
code transmissions. If the selected timeout expires and no transmission
has occurred, the Heartbeat message will be transmitted.
Select CSC, CMC, or P10 from the drop-down list. This defines the type of
Crisplant protocol to be used:
CSC: the <CR><LF> characters do not appear at the end of
transmitted/received telegrams
CMC: the <CR><LF> characters appear at the end of transmitted/received
telegrams
P10:
the <CR><LF> characters appear at the end of transmitted/received
telegrams
the Parameter Crisplant Manufacturer ID is forced to the Value ‘a’ (61H)
and cannot be modified for this selection
the error messages are modified with respect to CSC and CMC
protocols