E-GENIUS
159
4
Field Name
Action/Definition
No Phase
Timeout
Select Disable or a time interval in seconds or minutes from the drop-down list. If a
time interval is selected, a stuck sensor will report an error after the selected interval.
Protocol Index
Alarms
Select the check box to enable protocol index alarm messages.
Maximum
Consecutive
Lost Protocol
Indexes
Enter the number of consecutive lost protocol indexes allowed before an error is
reported.
Maximum % Of
Lost Protocol
Indexes
Enter the maximum percentage of lost protocol indexes allowed before an error is
reported.
PTP Time
Synchronization
Failure
Select the check box to report PTP (Precision Time Protocol) Time Synchronization
Errors.
Encoder Failure
Select the check box to report encoder (tachometer) errors.
Encoder
Timeout
Select Disable or a time interval in seconds or minutes from the drop-down list. If a
time interval is selected, a stuck encoder will report an error after the selected
interval.
3. When you have finished making changes, click Update All to save all pending changes,
click Reset All to revert to all previously saved values, and click Reset Page to revert to
previous saved values on the current page.