Multi Image Acquisition Settings
Product Reference Guide 141
Multi Image Acquisition Settings
When controlled variable conditions occur in the application, Multiple
Image
Acquisition Settings
can be defined to create a database of parameter groups
that handle each specific application condition. This database of pre-defined
settings improves system flexibility and readiness by being applied either
automatically or selectively by an activation event.
For example, an application may have several
stable but different lighting
conditions which require different lighting options. One Image Acquisition
Setting could enable and use an internal illuminator and another setting could
enable and use an external lighting system.
This feature is available for al
l Operating Modes.
Image Settings
are found in the DL.CODE Advanced Setup step. Up to 10
different Image Settings can be configured by adding them with the
icon.
For each Image Setting condition start Image Auto-Setup, select the Static or
Dynamic Self-Tuning option; and Apply it.