Environmental Features
Operating Temperature
a
a. high ambient temperature applications should use metal mounting bracket for heat dissi-
pation.
0 to 50 C (32 to 122 °F)
for liquid lens models: 0 to 45 °C (32 to 113 °F)
Storage Temperature -20 to 70 C
(-4 to 158 °F)
Max. Humidity 90% non condensing
Vibration Resistance
EN 60068-2-6
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 500 Hz; 2 hours on each axis
Bump Resistance
EN 60068-2-29
30g; 6 ms;
5000 shocks on each axis
Shock Resistance
EN 60068-2-27
30g; 11 ms;
3 shocks on each axis
Protection Class
b
b. when correctly connected to IP67 cables with seals.
EN 60529
IP65 and IP67
Environmental Features
Product Reference Guide 215
Environmental Features
Physical Features
Connector position 0° Connector position 90°
Dimensions
4xx-0xx models
95 x 54 x 43 mm
(3.7 x 2.1 x 1.7 in.)
7xx-0xx models
95 x 54 x 45 mm
(3.7 x 2.1 x 1.8 in.)
4xx-0xx models
75 x 54 x 62 mm
(3.0 x 2.1 x 2.4 in.)
7xx-0xx models
75 x 54 x 64 mm
(3.0 x 2.1 x 2.5 in.)
Weight
4xx-0xx models
about 238 g (8.4 oz.)
7xx-0xx models
236.5 - 274.5 g (8.3 - 9.7 oz.) depending on the model
Material Aluminum