Reset Reader to Factory Default Environment (Optional)
If it ever becomes necessary to reset the reader’s Environment parameters to
their factory default values, you can perform this procedure by holding the X-
PRESS push button pressed while powering up the reader. You must keep the X-
PRESS push button pressed until all LEDs blink simultaneously for about 3
seconds. Release and re-press the button during this LED blinking sequence.
All the device Environment parameters are reset including the default IP Address.
T
he Matrix 300N emits 3 high pitched beeps and after a few seconds enters run
mode.
Any previously saved configurations on the device will remain in memory, but
th
e Default configuration is set as the startup configuration.
NOTE
If you release the button while the LEDs are all on continuously (after the blinking
phase), the reader will enter the Loader program sequence and the LEDs will begin to
cycle through various patterns. Just cycle power to return to run mode.