EasyManuals Logo

Datalogic Matrix 300N User Manual

Datalogic Matrix 300N
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Product Reference Guide ix
Compliance
General
For installation, use and maintenance it is not necessary to open the reader.
Only connect Ethernet and dataport connections to a network which has routing
only within the plant or building and no routing outside the plant or building.
Power Supply
ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT
This product is intended to be installed by Qualified Personnel only.
This product is intended to be connected to a UL Listed Computer (LPS or “Class
2”) which supplies power directly to the reader, or a UL Listed Direct Plug-in
Power Unit (rated 10 to 30 V, minimum 1 A) marked LPS or “Class 2”, or Power
over Ethernet source Device supplied by UL Listed Direct Plug-in Power Unit
marked LPS or “Class 2”.
EMC Compliance
In order to meet the EMC requirements:
connect reader chassis to the plant earth ground by means of a flat copper
braid shorter than 100
mm;
connect pin "Earth" of the CBX connection box to a good Earth Ground;
for direct connections, connect your cable shield to the locking ring nut of
the connector.
CE Compliance
CE marking states the compliance of the product with essential requirements
listed in the applicable European directive. Since the directives and applicable
standards are subject to continuous updates, and since Datalogic promptly
adopts these updates, the EU declaration of conformity is a living document. The
EU declaration of conformity is available for competent authorities and custom
-
ers through Datalogic commercial reference contacts. The main European direc-
tives applicable to Datalogic products require inclusion of an adequate analysis
and assessment of the risk(s). This evaluation was carried out in relation to the
applicable points of the standards listed in the Declaration of Conformity. Data
-
logic products are mainly designed for integration purposes into more complex

Table of Contents

Other manuals for Datalogic Matrix 300N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Matrix 300N and is the answer not in the manual?

Datalogic Matrix 300N Specifications

General IconGeneral
TypeBarcode module bar barcode readers
Sensor typeCMOS
Scanner type1D/2D
Yaw reading angle0 - 24 °
Optical sensor resolution1024 pixels
Linear (1D) barcodes supported-
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, MaxiCode, Micro QR Code, QR Code
Input voltage10 - 30 V
Power consumption (typical)5 W
Connectivity technologyWired
CertificationAIM DPM, ISO/IEC 15415, ISO/IEC 15416, ISO/IEC 16022, ISO/IEC 18004, AS9132A
Product colorBlue, Metallic
Housing materialAluminium, Plastic
International Protection (IP) codeIP67
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Depth54 mm
Width75 mm
Height62 mm
Weight238 g

Related product manuals