CBX Electrical Connections
72
Matrix 300N
Auxiliary RS232 Interface
The RS232 auxiliary interface is available for Point-to-Point connections. When it
is connected to the host computer it allows transmission of code data.
The parameters relative to the aux interf
ace (baud rate, data bits, etc.) can be
defined through the Reading Phase step (Channels) in DL.CODE.
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred
co
nnector for temporary communication monitoring.
5
1
6
9
Figure 45 - 9-pin female connector
If permanent system wiring is required, the following pins are used to connect
the RS232 auxiliary interface:
CBX100/500 Description
TX Auxiliary Interface Transmit Data
RX Auxiliary Interface Receive Data
SGND Auxiliary Interface Reference
User Interface
RX TX
Reference
Figure 46 - RS232 Auxiliary Interface Connections
NOTE
Do not connect the Aux Interface to the CBX spring clamp connectors and the 9-pin
connector simultaneously.