EasyManua.ls Logo

Datalogic Matrix 300N - Power Supply; Standard Models; Power over Ethernet (Poe) Models

Datalogic Matrix 300N
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CBX Electrical Connections
62
Matrix 300N
Power Supply
Power requirements and conditions depend on the Matrix 300N model: Standard
or PoE (Power over Ethernet).
Standard Models
For these models power can be supplied to the reader through the CBX100/500
spring clamp terminal pins as shown in Figure 32:
Power Supply
Earth
Ground
V+ in
VGND
Figure 32 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by
set
ting the appropriate jumper in the CBX connection box. See the CBX
Installation Manual for details.
Power Over Ethernet (PoE) Models
The Ethernet pinout is as follows:
Figure 33 -
Pin Name Description
1 TX+/DC- Transmit data (+) DC power (-)
2 RX+/DC+ Received data (+) DC power (+)
3 TX-/DC- Transmitted data (-) DC power (-)
4 RX-/DC+ Receive data (-) DC power (+)
M12 D-Coded Female Ethernet Nerwork Connector