CBX Electrical Connections
66
Matrix 300N
RS422 Full Duplex Interface
The RS422 full-duplex (5 wires + shield) interface is used for non-polled
communication protocols in point-to-point connections over longer distances
(max 1200 m / 3940 ft) than those acceptable for RS232 communications or in
electrically noisy environments.
The CBX pinout follows:
CBX100/500 Description
TX+ RS422 Transmit Data +
RX+ RS422 Receive Data +
TX- RS422 Transmit Data -
RX- RS422 Receive Data -
SGND Signal Ground
User Interface
SGND
Reader
RX422- TX422-
TX422+
RX422+
TX- RX-
RX+
TX+SGND
Figure 39 - RS422 Full Duplex Connections
NOTE
User Interface
SGND
Reader
RX422-
RX422+
SGND TX+
TX-
Figure 40 - RS422 Full Duplex Connections Using Only TX Signals to Host
For applications that do not use RS422 transmission to the reader (terminal block RX+
and RX- signals), do not leave these lines floating but connect them to SGND as
shown below.