Step 6 - Device Configuration
Product Reference Guide 23
10.Click on the Data Matrix ECC 200 symbology under the Image Settings 
branch (enabled by default). If this symbology is among those in your appli-
cation it will be shown in the image display with its code symbology name 
an
d a small green box around it indicating it is decoded.
NOTE
11.Add your application specific codes to the Code Settings by selecting them 
from the icons over the Configuration Parameters tree area. If the Data 
Matrix symbology is not used, then delete it from the Code Settings with 
the Delete icon
.
If you don’t know the code type, you can use the Code Autolearn feature by 
cl
icking on the Code Autolearn icon
.
1
 See the DL.CODE User’s Manual for 
details.
12.For each code symbology set the relative parameters according to your 
application.
NOTE
The large green box for each symbol indicates the code localization area which by 
default is equal to the maximum FoV. It can be resized and moved by dragging its 
borders with the mouse. The code must be found within this area in order to be 
decoded.
1.  
The Code Autolearn procedure will not recognize the following symbologies: Pharmacode, MSI, 
Standard 2 of 5, Matrix 2 of 5.
Continue the configuration with the "Reading Phase" on page 31.