Loading...
ID-NET
Product Reference Guide 43
ID-NET Multidata: Multiple stations – single reader
ID-NET interface allows connection of readers reading objects placed on
independent conveyors. All readers are typically located far away from each
other and they can have different operating modes from each other.
At the end of each reading phase, each reader transmits its own data message to
t
he host. Thanks to ID-NET, data collection among readers is accomplished at a
high speed without the need of an external multiplexing device. This leads to an
overall cost reduction and to simple system wiring.
See "ID-N
ET Interface" on page 67 for connection details and "Internal Network
Configurations" on page 157 for configuration details.