Displaying PoE Settings and Statistics
ExtremeWare XOS 11.3 Concepts Guide
179
The detail command lists all inline power information for the selected ports. Detail output displays the
following information:
● Configured Admin State
● Inline Power State
● MIB Detect Status
● Label
● Operator Limit
● PD Class
● Max Allowed Power
● Measured Power
● Line Voltage
● Current
● Fault Status
● Detailed Status
● Priority
Following is sample output from the
show inline-power info port command:
Port State Class Volts Curr Power Fault
(mA) (Watts)
3:1 delivering class3 48.3 192 9.300 None
3:2 delivering class3 48.3 192 9.300 None
3:3 searching ------ 0.0 0 0.0 None
Following is sample output from the show inline-power info detail port command:
Port 3:1
Configured Admin State: enabled
Inline Power State : delivering
MIB Detect Status : delivering
Label :
Operator Limit : 16800 milliwatts
PD Class : class3
Max Allowed Power : 15.400 W
Measured Power : 9.400 W
Line Voltage : 48.3 Volts
Current : 193 mA
Fault Status : None
Detailed Status :
Priority : low
Displaying Port PoE Statistics
Use the following command to display the PoE statistics for each port:
show inline-power stats ports <port_list>